This guide covers Diamond road-tube vehicle counters. If you use Diamond TTC-4420 or TTC-4430 trail counters, see our Pedestrian Counter.
Which MetroCount counter replaces my Diamond model?
Every Diamond road-tube counter maps to the RoadPod VT, or to the RoadPod VT4 where two adjacent lanes in the same direction must be covered by one unit.
| Diamond counter* | Sensor | MetroCount replacement | What changes |
Traffic Tally 2, 4 and 6 (TT-2, TT-4, TT-6) | One road tube | Total counts become per-vehicle data. One tube gives volume; a second adds speed, class and direction | |
Omega G | Two road tubes | Battery power and reliability. In terms of data, this is the closest like-for-like: same two-tube, per-axle method. | |
| Omega X3 | Four road tubes | Same four-tube, per-axle method, with longer battery life and larger memory. | |
| Traffic Tally 200 (TT-200) | Inductive loops | Permanent loop sites; outside the scope of this guide. | |
| TTC-4420, TTC-4430 | Infrared beam and reflector | Fixed, solar-powered cabinet that also records walking direction and, paired with RidePod BP system, separates cyclists. |
*Diamond model descriptions from diamondtraffic.com and Diamond's Traffic Tally guide.
Diamond Traffic Tally 4 vs. RoadPod VT
The Traffic Tally 4 gives one total count; the RoadPod VT gives the same total plus speed, class, direction and timing for every vehicle.
| Feature | Diamond Traffic Tally 4* | RoadPod VT |
| Sensors | One road tube | Two road tubes (one possible for volume only) |
| Output | Grand total over a programmed period | Every axle timestamped, analyzed into any time interval |
| Speed | No | Yes |
| Vehicle classification | No | Yes: FHWA 13 and 30+ others |
| Direction | No | Yes |
| Peak hours and time-of-day trends | No | Yes |
| Analysis software | Simple readout | MTE and ATLYST |
| Manufacturer support | Manufacturer closed February 27, 2026 | Supported, with a US office in Glen Burnie, Maryland |
*Traffic Tally 4 functions from Diamond's published Traffic Tally guide.
Can the RoadPod VT just give me a total like my Traffic Tally?
Yes. Install the VT with one tube, and it records volume only, like a Traffic Tally. MetroCount recommends two tubes even for volume surveys, because a second tube adds redundancy and more accurate vehicle counts on roads where trucks are common.
What is the RoadPod VT?
The RoadPod VT is MetroCount's portable pneumatic road-tube counter and classifier, built for short-term traffic surveys on anything from highways to unsealed rural roads. It replaced the MC5600 counter in 2009. A few years later, MetroCount launched the RoadPod VT4, a four-tube counter that covers two adjacent traffic lanes.
| Specification | RoadPod VT / RoadPod VT4 | ![]() | |
| Sensors | Two (or four) pneumatic road tubes (natural rubber) | ||
| Tube spacing | between 31–47", typically 3ft | ||
| Time resolution | Better than 1 ms | ||
| Memory | Up to 4 million axle events | ||
| Power | 4 alkaline D cells | ||
| Battery life | Up to 4 years of continuous use (approx. 60 days at 16,000 vehicles per lane per day) | ||
| Data outputs | Volume, speed, vehicle class, direction, gaps between vehicles, VT4-Lane | ||
| Classification schemes | FHWA 13 and 30+ others | ||
| Analysis software | MTE, with ATLYST for cloud reporting | ||
| Remote download | Optional Remote Access Link** | ||
| Enclosure* | Stainless steel road case, weather-resistant inner case | ||
| Road case size | 350 × 124 × 95 mm (13.8 × 4.9 × 3.7 in) | ||
| Main unit size | 243 × 107 × 82 mm (9.6 × 4.2 × 3.2 in) | ||
| Weight | About 4.15 kg (9.1 lb) | ||
| Operating temperature | −20 °C to 70 °C (−4 °F to 158 °F) | ||
| Operating humidity | 0–95% |
*An optional MetroCount Handle case is 56% lighter than the standard road case.
**Recommended for surveys of 3 months or more
How accurate is the RoadPod VT?
Independent university studies measured MetroCount two-tube counters at 97–100% volume accuracy, 92–98% classification accuracy and about 95% speed accuracy. In the same North Dakota State University study, a single-tube Diamond Traffic Tally 6 overcounted vehicles by up to 31.6%.
| Study | Device tested | Site | Volume | Classification | Speed |
| MetroCount MC5600 (VT predecessor) | Two-lane arterial, one lane, Fargo ND | 100% (0.0% difference) | 98.1% (1.9% misclassified) | Not tested | |
| Same study | MC5600 | Two-lane arterial, both lanes, Fargo ND | 99.7–100% | 92.0% | Not tested |
| Same study | MC5600 | Four-lane arterial, Fargo ND | 97.0% | 93.7% | Not tested |
| RoadPod VT 5900 and VT4 5904 | Bangalore University campus, Bengaluru | 96.5% average (volume and class) | 96.5% average (volume and class) | About 95% | |
| MetroCount tube counters | Florida | No significant difference from actual volumes (95% confidence) | Not reported | Not reported |
Switching from Diamond to MetroCount
Most Diamond field hardware carries over; the road tubes, software and data workflow change.
Field hardware
- Nails, clamps and other tube fixings: reusable with the RoadPod VT.
- Road tubes: replace with tubes specified for the VT. MetroCount supplies natural rubber tubes that perfectly fit the hardware.
- Unsealed roads: the VT works on dirt and gravel. Use 8″ deck spikes or 4″ coach screws instead of road nails, and run the tube through lay-flat hose to protect it.
Can I import my historical Diamond data?
No. MetroCount software cannot import Diamond or Centurion data files, and MetroCount does not offer a Diamond data recovery service. Your historical counts remain usable in the formats you already hold, so the priority is to secure them before you retire your Diamond equipment.
Before you switch:
- Export your history from Centurion now. Centurion can export to more than 12 formats, including Excel. Export both the raw per-vehicle files and the summary reports you publish.
- Download any data still stored on counters, Datahogs or the Diamond Data Server.
- Keep one PC with Centurion and its license as a read-only archive, so older files can still be opened.
- Run an overlap survey (see below) at your key sites, so you can line up the new trend line with the old one.
From your first RoadPod VT survey, every vehicle is stored with its own timestamp, speed and class.
Run an overlap survey before switching fully
If you are extending a long-term count history, run your Diamond counter and a RoadPod VT at the same site for at least one full week, covering weekdays and a weekend. Check both against a manual or video count for a few peak hours. This shows how the new data compares to the old before you rely on it for trend reporting.
Software and support
RoadPod VT data is analyzed in MTE (MetroCount Traffic Executive) on a PC and/or with ATLYST for cloud reporting and sharing. An ATLYST subscription includes MTE and free technical support.
Frequently asked questions
What is the best replacement for a Diamond Traffic Tally counter?
The MetroCount RoadPod VT uses the same pneumatic road tubes, can record volume with one tube like a Traffic Tally, and adds speed, class and direction when a second tube is installed.
What replaces the Diamond Omega G counter?
The RoadPod VT replaces the Omega G for one lane or a two-way road with no median. Where two adjacent lanes in the same direction must be covered by one unit, use the RoadPod VT4.
Who uses the RoadPod VT in the United States?
MetroCount tube counters are used by US state departments of transportation and by traffic data contractors, including Southern Traffic Services.
- Southern Traffic Services (STS), part of Rekor Systems since July 2022, manages more than 30,000 traffic data collection sites across US states.
- State DOTs using MetroCount counters: New York State, Florida DOT District 3, South Carolina, West Virginia and Georgia (both still using the older MC5600 model of counters).
- Over 25,000 MetroCount counters are currently in use across the US.
How does a two-tube counter calculate speed?
It divides the distance between the tubes, usually 3 ft, by the time between an axle hitting the first and second tube. The RoadPod VT timestamps each hit to better than 1 millisecond.
How many lanes can one RoadPod VT cover?
One lane, or a two-way road with no median, for speed and class data. On busy roads, MetroCount recommends one counter per lane, or the RoadPod VT4 for two lanes in the same direction.
How long can a RoadPod VT stay in the field?
The batteries last up to 4 years of continuous use. Memory holds up to 4 million axle events, roughly 60 days at 16,000 vehicles per lane per day.
Can I reuse my Diamond road tubes?
No. Use tubes specified for the RoadPod VT. You can reuse your existing nails and clamps.
Can I import my Diamond or Centurion data into MetroCount software?
No. MetroCount software cannot read Diamond or Centurion files, and we don't offer a data recovery service. Export your history from Centurion, which supports Excel and other formats, and keep it as your archive.
Does the RoadPod VT work on gravel roads?
Yes. Use 8″ deck spikes or 4″ coach screws instead of road nails, protect the tube with lay-flat hose, and check the site weekly.
Can I download data without visiting the site?
Yes. The optional Remote Access Link automatically sends data from the counter to a computer running MetroCount software. The Link is recommended for survey periods of 3 months or more as it allows you to check the site health remotely and take any actions necessary to avoid data outages.
MetroCount also offers remote data delivery services that can manage this process for you.
Is MetroCount's software included?
MTE analysis software and technical support are included with an ATLYST subscription.
Can I rent a RoadPod VT?
Yes, the RoadPod VT is available to rent. For ongoing count programs, MetroCount recommends buying a counter that will last 10+ years.
Got a great MetroCount story? Share it with us and let the world know the great work you're doing in your community.